Fiberglass Batts vs. Blown-In Insulation: Which Is Better?

Written by Noah Hayes, Home Improvement Writer · Published September 25, 2026 · Updated October 21, 2026

Short answer: For most existing attics, we recommend blown-in fiberglass. It flows around wiring, pipes, ducts and uneven joists, it tops up old insulation in one even layer, and on our planning prices it costs about the same as batts ($1.00 to $2.10 per sq ft vs. $0.80 to $2.20). Batts are the better pick for open walls, floors over a crawl space, garages and simple attics with open, evenly spaced joists, especially if you are doing it yourself. Both are the same fiberglass. What changes is how it goes in and how well it fills the space.

These are our planning prices, not quotes. Your final price comes after the free on-site assessment. We install both, and our fiberglass insulation in San Antonio page shows where each one fits.

Batts vs. Blown-In at a Glance

Fiberglass batts and rollsBlown-in fiberglass
What it isPrecut blankets (batts) or long blankets you cut (rolls)Loose fibers blown in with a machine
R-value per inchabout R-3.1 to R-3.8about R-2.2 to R-2.7 on an attic floor
R-value comes fromThe label on the batt, if it is not squashedDepth and bag count from the bag's coverage chart
Best forOpen walls, floors, garages, open attics with even joistsExisting attics, attics with obstructions, topping up
Around wiring and pipesMust be cut and split to fit, or it leaves gapsFills around them on its own
SettlingNoneVery little, about 2% to 4%
DIYYes, basic skill, no machinePossible with a rented blower, messier
Our planning price per sq ft$0.80 to $2.20 (about $1.70 typical)$1.00 to $2.10 (about $1.60 typical)

Batts pack more R-value into each inch, but blown-in usually wins in a real attic because it leaves fewer gaps. A small gap matters more than most people expect, because heat takes the easiest path.

Fiberglass Batt vs. Blown-In Thickness Chart

This chart shows the typical depth for each attic R-value. For batts, it shows the standard thickness or a common two-layer combination. For blown-in, it shows the range we found across common products' coverage charts.

R-valueUnfaced fiberglass battsBlown-in fiberglassBlown-in cellulose
R-30One R-30 batt, about 9.5 to 10.25 inabout 10.5 to 12.5 inabout 9 in installed (about 8.25 in settled)
R-38One R-38 batt, about 12 to 12.5 in, or two R-19 layers, about 12.5 to 13 inabout 13.25 to 15.5 inabout 11.25 to 11.5 in installed (about 10.5 in settled)
R-49One R-49 batt, about 13.5 to 14 in (not always stocked), or R-30 plus R-19, about 15.75 to 16.75 inabout 18 to 22 inabout 14.25 to 14.5 in installed (about 13.25 in settled)
R-60R-30 plus R-30, about 19 to 20.5 inabout 20 to 22.75 inabout 17.25 to 17.75 in installed (about 16 in settled)

How to read it:

  • Always check the bag's coverage chart. Every blown-in product lists its own minimum depth and minimum number of bags per 1,000 sq ft for each R-value. You need both. Enough depth with too few bags means the layer is too fluffy to reach the R-value.
  • Check the attic card. After a blown-in job, the code requires depth markers in the attic and a certificate near the access that lists the depth, R-value and bags used. Use it to confirm what was installed.
  • Batt layers add up. Two layers give you the sum of their R-values, as long as neither is squashed. Lay the top layer across the joists.
  • Cellulose settles more than fiberglass, so it goes in deeper than its settled depth.

For the full guide to how much you need and how to measure what you have, see our how much attic insulation guide.

When Blown-In Fiberglass Is the Better Choice

Blown-in is our default for an existing attic, for four reasons:

  • It fills around everything. Wiring, plumbing vents, duct boots, cross bracing and odd joist spacing are normal in an attic. Loose fibers flow around them. Batts have to be cut and split around each one, and the gaps that get left behind cost R-value.
  • It tops up cleanly. Most attics already have some insulation, often uneven. Blown-in goes over it and levels it out to one depth.
  • It covers fast. A crew can blow a typical attic in a few hours, and there are no seams between pieces.
  • It reaches low eaves. A hose reaches spots near the roof edge that are hard to crawl to with batts. Rafter vents (baffles) go in first so the eave vents stay open.

The trade-off is depth. Loose fiberglass has the lowest R-value per inch on this list, so it needs more inches for the same R-value. Check that the attic has the room, especially near the eaves.

When Batts Are the Better Choice

Batts make sense where the framing is open and regular:

  • Open walls in a remodel, addition or garage. Batts are the standard choice for open wall cavities: R-13 or R-15 for 2x4 walls and R-19 to R-21 for 2x6 walls, depending on the product.
  • Floors over a crawl space or garage, held in place against the subfloor.
  • Simple attics with open, evenly spaced joists and few obstructions.
  • Small or partly floored attics where only some areas need insulation.
  • DIY jobs. ENERGY STAR rates batts and rolls as a basic skill level, and you do not need a machine.

Batts only reach their labeled R-value when they fill the space with no gaps and no squashing. Cut them to fit snugly around outlets, wires and pipes. Do not stuff them.

Schedule your free on-site assessment and get a free estimate for your attic. Prefer a quick number now? Try our insulation calculator below.

Batts vs. Rolls: What Is the Difference?

They are the same material. Batts are precut lengths, often 4 feet or just under 8 feet. Rolls are one long blanket you cut to length on site. Rolls are faster on long, open joist runs, and batts are easier to handle in tight spots.

Both come faced or unfaced. Faced products have a kraft paper or foil layer on one side that slows moisture. In an attic, use unfaced, especially when adding a layer over existing insulation. A facing on top of old insulation can trap moisture between the layers.

Mixing Batts and Blown-In

You can combine them. ENERGY STAR notes you can add loose-fill over batts or batts over loose-fill.

  • Blown-in over old batts is the most common top-up we see recommended. It fills the gaps between and around the old batts and levels the attic.
  • Unfaced batts over blown-in work too. Lay them across the joists, and do not squash the layer below.
  • Do not add anything over wet, moldy or animal-soiled insulation. That part has to come out first.

Whatever you add, seal the air leaks in the ceiling first. Insulation slows heat, but it does not stop air.

What About Walls?

In an open wall, batts are the standard, low-cost choice. In a closed wall, batts would mean removing the drywall. Instead, blown insulation can be packed tightly into each cavity through small holes. Dense-packed fiberglass reaches a much higher R-value per inch than loose fiberglass on an attic floor because it is packed tighter. Dense-packing is a job for a trained installer, because the density has to be right for the R-value and to keep it from settling. See our wall insulation service for how we look at closed-wall projects.

What Does Each Cost?

On our planning prices, the two are close for an attic floor:

1,500 sq ft atticLow to high (typical)
Fiberglass batts$1,200 to $3,300 ($2,550)
Blown-in fiberglass$1,500 to $3,150 ($2,400)

Batts can look cheaper per bag at the store, but in an attic with obstructions the labor of cutting and fitting each piece adds up. Blown-in goes in faster. The final number depends on the R-value you are aiming for, the depth already there, access and whether old insulation has to come out first, which is extra. These are planning prices, not quotes and not figures from our completed jobs. Your final price comes after the free on-site assessment.

Schedule your free on-site assessment and get a free estimate for your attic. Prefer a quick number now? Try our insulation calculator below.

Calculate Your Insulation Cost in 60 Seconds

Open the calculator

Batts vs. Blown-In for Texas and San Antonio Homes

San Antonio is in climate zone 2. Texas code requires R-38 in a new attic ceiling in this zone, and we recommend R-38 to R-49 for most attics. Many Texas homes also have the air conditioner and ducts in the attic. That makes blown-in the practical choice for most attic top-ups here: it fills around the duct boots and supports instead of leaving gaps where batts would have to be cut.

Batts still have a place in Texas homes, mainly in open walls during a remodel, garage conversions and floors over a crawl space. If you are deciding between batts and blown-in, our fiberglass insulation in San Antonio service covers both, and we check the attic before recommending either.

For a closer look at the two loose-fill options, see our comparison of fiberglass vs. cellulose.

Schedule your free on-site assessment and get a free estimate for your attic. Prefer a quick number now? Try our insulation calculator below.

Safety First

  • Fiberglass irritates skin, eyes and lungs. ENERGY STAR recommends a disposable coverall, gloves, eye protection and a particulate respirator or double-strap dust mask.
  • Texas attics get very hot. Work early in the morning, take breaks and drink water.
  • Step only on joists or truss chords, never on the drywall between them.
  • Keep insulation at least 3 inches from recessed lights unless they are rated for insulation contact (IC).
  • If you see gray-brown or silver-gold pebbles, it may be vermiculite. The EPA advises leaving it alone and getting professional advice.

Common Mistakes

  • Squashing batts into a shallower space, which lowers the R-value.
  • Leaving gaps at batt ends and around wires and pipes.
  • Putting a faced batt on top of existing insulation. Added layers should be unfaced.
  • Blowing to depth with too few bags. Check both numbers on the bag chart.
  • Blocking the eave vents. Install baffles first.
  • Skipping air sealing. Neither batts nor blown-in stop air leaks.

Get a Free Estimate for Your Attic

Batts or blown-in, the right choice depends on your framing, what is already there and how much room you have. Schedule your free on-site assessment and get a free estimate for your attic. Prefer a quick number now? Try our insulation calculator below.

Calculate Your Insulation Cost in 60 Seconds

Open the calculator

Get a Free Quote | Call (445) 270-7997 | Free Estimates

Frequently Asked Questions

Is blown-in insulation better than batts?

For most existing attics, yes. It fills around wiring, pipes and ducts with fewer gaps and tops up old insulation evenly. Batts are better for open walls, floors and simple attics with open, even joists.

Is blown-in insulation better than rolls?

In most attics, yes, for the same reason: fewer gaps. Rolls are a good DIY choice on long, open joist runs with few obstructions.

Which is cheaper, batts or blown-in?

They are close. Our planning prices are $0.80 to $2.20 per sq ft for batts and $1.00 to $2.10 for blown-in fiberglass. In an attic with obstructions, blown-in often costs less to install.

How thick should blown-in insulation be?

It depends on the product and the R-value. For blown-in fiberglass, R-38 is about 14 to 17 inches and R-49 about 18 to 22 inches. Fiberglass batts are thinner at the same R-value (about 12 to 12.5 inches at R-38 and 13.5 to 14 inches for a single R-49 batt). Always follow the bag's chart.

How thick is an R-30 or R-38 batt?

An R-30 batt is about 9.5 to 10.25 inches thick, and an R-38 batt is about 12 to 12.5 inches. Check the label, because it varies by product.

Can you put blown-in insulation over batts?

Yes. It is a common way to top up an attic. Make sure the old batts are dry and clean, and seal the air leaks first.

Can you put batts over blown-in insulation?

Yes. Use unfaced batts, lay them across the joists and do not squash the layer below.

Does blown-in fiberglass settle?

Very little, about 2% to 4%. Cellulose settles more, which is why its charts list a deeper installed depth.

How We Set These Numbers

Our recommendations, depths and planning prices come from our research of official guidance, code text, product coverage data and national and Texas market data, and we review them as we complete jobs. Depths are typical ranges, not a specification for your attic. Prices are planning prices, not quotes and not figures from our completed jobs; your final price comes after the free on-site assessment.

Official sources we use:

  • U.S. Department of Energy, insulation materials guidance and Building America Solution Center guides on loose-fill and batt insulation
  • ENERGY STAR, "Choosing the Appropriate Insulation Type", "A Do-It-Yourself Guide to Sealing and Insulating" and "Well-Insulated and Sealed Attic"
  • International Code Council, International Energy Conservation Code, Section R303.1.1.1 (depth markers for blown-in insulation) and Section R303.1.2 (insulation certificate)
  • Federal Trade Commission, R-Value Rule
  • Texas State Energy Conservation Office, residential energy code
  • U.S. Environmental Protection Agency, vermiculite insulation guidance